Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Int J Hyg Environ Health ; 245: 114017, 2022 08.
Article in English | MEDLINE | ID: covidwho-1966623

ABSTRACT

Viral pandemics can be inevitable in the next future. Considering SARS-CoV-2 pandemics as an example, there seems to be a need to develop a surveillance system able to monitor the presence of potential pathogenic agents. The sewage and wastewater environments demonstrated to be suitable targets for such kind of analysis. In addition, it is important to have reliable molecular diagnostic tools and also to develop a robust detection strategy. In this study, an effective sample preparation procedure was selected from four options and combined with a newly developed improved RT-PCR. First, a model viral system was constructed, containing a fragment of the SARS-CoV-2 gene encoding for the Spike protein. The encapsidated S RNA mimic (ESRM) was based on the plum pox virus (PPV) genome with the inserted targeted gene fragment. ESRM was used for seeding wastewater samples in order to evaluate the viral recovery of four different viral RNA concentration/extraction methods. The efficiency of individual approaches was assessed by the use of a quantitative reverse transcription PCR (qRT-PCR) and by a one-step single-tube nested quantitative reverse transcription PCR (OSN-qRT-PCR). For the detection of viruses in wastewater samples with low viral loads, OSN-qRT-PCR assay produced the most satisfactory results and the highest sensitivity.


Subject(s)
COVID-19 , Pandemics , COVID-19/diagnosis , COVID-19 Testing , Humans , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Wastewater
2.
Sci Total Environ ; 848: 157613, 2022 Nov 20.
Article in English | MEDLINE | ID: covidwho-1956330

ABSTRACT

Several virus concentration methods have been developed to increase the detection sensitivity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater, as part of applying wastewater-based epidemiology. Polyethylene glycol (PEG) precipitation method, a method widely used for concentrating viruses in wastewater, has some limitations, such as long processing time. In this study, Pegcision, a PEG-based method using magnetic nanoparticles (MNPs), was applied to detect SARS-CoV-2 in wastewater, with several modifications to increase its sensitivity and throughput. An enveloped virus surrogate, Pseudomonas phage φ6, and a non-enveloped virus surrogate, coliphage MS2, were seeded into wastewater samples and quantified using reverse transcription-quantitative polymerase chain reaction to assess the recovery performance of the Pegcision. Neither increasing MNP concentration nor reducing the reaction time to 10 min affected the recovery, while adding polyacrylic acid as a polyanion improved the detection sensitivity. The performance of the Pegcision was further compared to that of the PEG precipitation method based on the detection of SARS-CoV-2 and surrogate viruses, including indigenous pepper mild mottle virus (PMMoV), in wastewater samples (n = 27). The Pegcision showed recovery of 14.1 ± 6.3 % and 1.4 ± 1.0 % for φ6 and MS2, respectively, while the PEG precipitation method showed recovery of 20.4 ± 20.2 % and 18.4 ± 21.9 % (n = 27 each). Additionally, comparable PMMoV concentrations were observed between the Pegcision (7.9 ± 0.3 log copies/L) and PEG precipitation methods (8.0 ± 0.2 log copies/L) (P > 0.05) (n = 27). SARS-CoV-2 RNA was successfully detected in 11 (41 %) each of 27 wastewater samples using the Pegcision and PEG precipitation methods. The Pegcision showed comparable performance with the PEG precipitation method for SARS-CoV-2 RNA concentration, suggesting its applicability as a virus concentration method.


Subject(s)
COVID-19 , Magnetite Nanoparticles , Humans , Polyethylene Glycols , RNA, Viral , SARS-CoV-2 , Tobamovirus , Wastewater
3.
Sci Total Environ ; 807(Pt 2): 150722, 2022 Feb 10.
Article in English | MEDLINE | ID: covidwho-1447139

ABSTRACT

Polyethylene glycol (PEG) precipitation is one of the conventional methods for virus concentration. This technique has been used to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in wastewater. The procedures and seeded surrogate viruses were different among implementers; thus, the reported whole process recovery efficiencies considerably varied among studies. The present study compared five PEG precipitation procedures, with different operational parameters, for the RT-qPCR-based whole process recovery efficiency of murine hepatitis virus (MHV), bacteriophage phi6, and pepper mild mottle virus (PMMoV), and molecular process recovery efficiency of murine norovirus using 34 raw wastewater samples collected in Japan. The five procedures yielded significantly different whole process recovery efficiency of MHV (0.070%-2.6%) and phi6 (0.071%-0.51%). The observed concentration of indigenous PMMoV ranged from 8.9 to 9.7 log (8.2 × 108 to 5.6 × 109) copies/L. Interestingly, PEG precipitation with 2-h incubation outperformed that with overnight incubation partially due to the difference in molecular process recovery efficiency. The recovery load of MHV exhibited a positive correlation (r = 0.70) with that of PMMoV, suggesting that PMMoV is the potential indicator of the recovery efficiency of SARS-CoV-2. In addition, we reviewed 13 published studies and found considerable variability between different studies in the whole process recovery efficiency of enveloped viruses by PEG precipitation. This was due to the differences in operational parameters and surrogate viruses as well as the differences in wastewater quality and bias in the measurement of the seeded load of surrogate viruses, resulting from the use of different analytes and RNA extraction methods. Overall, the operational parameters (e.g., incubation time and pretreatment) should be optimized for PEG precipitation. Co-quantification of PMMoV may allow for the normalization of SARS-CoV-2 RNA concentration by correcting for the differences in whole process recovery efficiency and fecal load among samples.


Subject(s)
Bacteriophages , COVID-19 , Murine hepatitis virus , Animals , Humans , Mice , Polyethylene Glycols , RNA, Viral , SARS-CoV-2 , Tobamovirus , Wastewater
4.
J Virol Methods ; 297: 114249, 2021 11.
Article in English | MEDLINE | ID: covidwho-1331022

ABSTRACT

In the pandemic of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) many strategies have been performed in order to control viral spread in the population and known the real-time situation about the number of infected persons. In this sense, Wastewater Based Epidemiology (WBE) has been applied as an excellent tool to evaluate the virus circulation in a population. In order to obtain reliable results, three low-cost viral concentration methods were evaluated in this study, polyethylene glycol (PEG) precipitation, skimmed milk flocculation (SM) and Aluminum polychloride flocculation, for Pseudomonas aeruginosa bacteriophage PP7 as a surrogate for non-enveloped viruses and Bovine Coronavirus (BCoV) as a surrogate for enveloped virus, with emphasis for SARS- CoV-2. Our results suggest that PEG precipitation for viral concentration, for both enveloped and non-enveloped virus from wastewater is an appropriate approach since it was more sensitive compared to SM flocculation and Aluminum polychloride flocculation. This methodology can be used for WBE studies in order to follow the epidemiology of the SARS-CoV-2 pandemic, mainly in developing countries where the economic resources are frequently limited.


Subject(s)
COVID-19 , Viruses , Animals , Cattle , Humans , Pandemics , SARS-CoV-2 , Wastewater
5.
Sci Total Environ ; 758: 143870, 2021 Mar 01.
Article in English | MEDLINE | ID: covidwho-968693

ABSTRACT

Wastewater based epidemiology (WBE) has emerged as a reliable strategy to assess the coronavirus disease 2019 (COVID-19) pandemic. Recent publications suggest that SARS-CoV-2 detection in wastewater is technically feasible; however, many different protocols are available and most of the methods applied have not been properly validated. To this end, different procedures to concentrate and extract inactivated SARS-CoV-2 and surrogates were initially evaluated. Urban wastewater seeded with gamma-irradiated SARS-CoV-2, porcine epidemic diarrhea virus (PEDV), and mengovirus (MgV) was used to test the concentration efficiency of an aluminum-based adsorption-precipitation method and a polyethylene glycol (PEG) precipitation protocol. Moreover, two different RNA extraction methods were compared in this study: a commercial manual spin column centrifugation kit and an automated protocol based on magnetic silica beads. Overall, the evaluated concentration methods did not impact the recovery of gamma-irradiated SARS-CoV-2 nor MgV, while extraction methods showed significant differences for PEDV. Mean recovery rates of 42.9 ± 9.5%, 27.5 ± 14.3% and 9.0 ± 2.2% were obtained for gamma-irradiated SARS-CoV-2, PEDV and MgV, respectively. Limits of detection (LoD95%) for five genomic SARS-CoV-2 targets (N1, N2, gene E, IP2 and IP4) ranged from 1.56 log genome equivalents (ge)/mL (N1) to 2.22 log ge/mL (IP4) when automated system was used; while values ranging between 2.08 (N1) and 2.34 (E) log ge/mL were observed when using column-based extraction method. Different targets were also evaluated in naturally contaminated wastewater samples with 91.2%, 85.3%, 70.6%, 79.4% and 73.5% positivity, for N1, N2, E, IP2 and IP4, respectively. Our benchmarked comparison study suggests that the aluminum precipitation method coupled with the automated nucleic extraction represents a method of acceptable sensitivity to provide readily results of interest for SARS-CoV-2 WBE surveillance.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Humans , Pandemics , RNA , Swine , Wastewater
6.
Sci Total Environ ; 756: 143067, 2021 Feb 20.
Article in English | MEDLINE | ID: covidwho-867105

ABSTRACT

The primary concentration and molecular process are critical to implement wastewater-based epidemiology for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, the previously developed methods were optimized for nonenveloped viruses. Few studies evaluated if the methods are applicable to the efficient recovery of enveloped viruses from various types of raw sewage. This study aims (1) to compare the whole process recovery of Pseudomonas phage φ6, a surrogate for enveloped viruses, among combinations of primary concentration [ultrafiltration (UF), electronegative membrane vortex (EMV), and polyethylene glycol precipitation (PEG)] and RNA extraction methods (spin column-based method using QIAamp Viral RNA Mini Kit and acid guanidinium thiocyanate-phenol-chloroform extraction using TRIzol reagent) for three types of raw sewage and (2) to test the applicability of the method providing the highest φ6 recovery to the detection of SARS-CoV-2 RNA. Among the tested combinations, PEG+TRIzol provided the highest φ6 recovery ratio of 29.8% to 49.8% (geometric mean). UF + QIAamp Viral RNA Mini Kit provided the second highest φ6 recovery of 6.4% to 35.8%. The comparable φ6 recovery was observed for UF + TRIzol (13.8-30.0%). PEG + QIAamp Viral RNA Mini Kit provided only 1.4% to 3.0% of φ6 recovery, while coliphage MS2, a surrogate for nonenveloped viruses, was recovered comparably with PEG + TRIzol. This indicated that the nonenveloped surrogate (MS2) did not necessarily validate the efficient recovery for enveloped viruses. EMV + QIAamp Viral RNA Mini Kit provided significantly different φ6 recovery (1.6-21%) among the types of raw sewage. Then, the applicability of modified PEG + TRIzol was examined for the raw sewage collected in Tokyo, Japan. Of the 12 grab samples, 4 were positive for SARS-CoV-2 CDC N1 and N3 assay. Consequently, PEG + TRIzol provided the highest φ6 recovery and allowed for the detection of SARS-CoV-2 RNA from raw sewage.


Subject(s)
COVID-19 , Wastewater , Chloroform , Guanidines , Humans , Japan , Phenol , Phenols , Polyethylene Glycols , SARS-CoV-2 , Thiocyanates , Tokyo
SELECTION OF CITATIONS
SEARCH DETAIL